EVAPORATOR COIL That part of an evaporator constructed of pipe or tubing not enclosed in a pressure vessel. EVAPORATIVE CONDENSER A condenser that obtains cooling effect by the evaporation of water in an air stream on the external surface of the tubes for the heat removal necessary to liquefy refrigerant vapor on the inside of the tubes.

[email protected]
News Detail
  • Anhydrous Ammonia System Piping Requirements

    As a rule of thumb pipe supports are installed every 10 feet, plus one foot for each inch of pipe diameter. For example, for 2-inch diameter piping; 10 feet + [2 in. diameter pipe X 1 ft./in. pipe diameter] = 12 feet

    Get Price
  • Anhydrous Ammonia System Piping Requirements

    10 feet + [2 inch diameter pipe X 1 foot/inch pipe diameter] = 12 feet. PRESSURE RELIEF PROTECTION Pressure relief protection for system piping and hosing must be provided by means of 350-400 psi/NH3-rated hydrostatic relief valves or hydrostats. Hydrostats must be installed in each section of liquid and vapor system piping and

    Get Price
  • Squibb Taylor, Inc.

    Squibb Taylor, Inc.

    Get Price
  • ASME B31.3 Process Piping Guide - Los Alamos National Laboratory

    pipe supports, material traceability, gasket selection, as-built tolerances, insulation, cleaning for special process, etc. Also, for certain services some options available through B31.3 must be excluded, made more stringent or supplemented by the designer.

    Get Price
  • Fertilizer Knife Catalog - Wiese Industries

    Jun 24, 2013 · Flared insert at the bottom of the knife creates a pocket for NH3. Universal punching fits most side-mount applicator shanks, including DMI, Blu-Jet, etc. 3/8” and 1/2” anhydrous pipes are crimped and cross-drilled.

    Get Price
  • Refrigerant Piping Design Guide - Homestead

    As refrigerant flows through pipes the pressure drops and changes the refrigerant saturation temperature. Decreases in both pressure and saturation temperature adversely affect compressor performance. Proper refrigeration system design attempts to minimize this change to less than 2°F (1.1°C) per line.

    Get Price
  • System Design for Industrial Ammonia/CO Cascade Installations

    Pipe and vessel sizing will be discussed more detailed below. Operating pressure for CO 2 is significantly higher than for ammonia for equal application temperatures, requiring more substantial compressors, vessels, valves, etc. In addition, a cascade system requires an expensive CHE instead of a relatively inexpensive intercooler or economizer

    Get Price
  • NFPA 58

    NFPA 58 Liquefied Petroleum Gas Code 1998 Edition National Fire Protection Association, 1 Batterymarch Park, PO Box 9101, Quincy, MA 02269-9101 An International Codes and Standards Organization

    Get Price
  • Pipe Color Codes - ANSI/ASME A13.1 | Creative Safety Supply

    ANSI/ASME A13.1 Pipe Marking Standard. Pipe color-coding is not a complicated process, especially if industry standards are used. There are many standards out there from a variety of sources, but by far the most popular is the ANSI /ASME A13.1 standard.

    Get Price
  • CUSTOMER MANUAL – AQUA AMMONIA TABLE OF CONTENTS

    TOTAL VAPOR PRESSURE OF AQUA AMMONIA SOLUTIONS (Expressed in Pounds Absolute): TEMPERATURE OF SOLUTION IN °F % NH 3 32 40 50 60 70 80 90 100 110 120 2.2--- .3 .5 .7 1.0 1.3 1.7 2.2 2.8

    Get Price
  • CUSTOMER MANUAL – ANHYDROUS AMMONIA

    ANHYDROUS AMMONIA PROPERTIES Anhydrous am monia is the compound formed by the combination of the two gaseous elements, nitrogen and hydrogen, in the proportion of one part of nitrogen to three parts of hydrogen by volume.

    Get Price
  • DOT US Department of Transportation PHMSA Pipeline and

    welder started to weld on the TOR, the pipe began moving upward in the ditch and buckled. When the pipe buckled, a corresponding wrinkle formed (located upstream of the buckle 10.5 ft). The pipe cracked in the buckle area. The pipe moved vertically upward at the failure location for 3.19 feet. The buckle occurred 62 feet from a road crossing .

    Get Price
  • PROJECT STANDARDS AND SPECIFICATIONS piping systems Rev01

    A Area of cross-sectional of pipe, in (m²) Am Minimum pipe cross-sectional flow area required, in (mm per m³/h liquid flow) Amm Cross-section of pipe, in (mm²) Bd Rate of flow in barrels (42 U.S gallons)per day Bh Rate of flow in barrels (42 U.S gallons) per hour BX B Y Baker parameters C Hazen-Williams constant

    Get Price
  • Objectives Ammonia Refrigeration Processes Equipment

    • Since NH3 properties include fire/explosion potential it is conceivable that a release resulting in a fire/explosion from one system could affect the other co-located systems (especially since the bulk of NH3 systems are located indoors) • If the systems are in separate areas of the facility and not

    Get Price
  • This section contains a number of frequently asked questions

    a data plate and be approved for Nh3 storage with a minimum working pressure of 250 psig. All storage tanks must be built according to ASME Code and have a National Board Code Inspector stamp, or in lieu of the NBIC number, an ASME manufacturer’s data report direct from the manufacturer. Or, the storage

    Get Price
  • Guidelines for: Start-up, Inspection and Maintenance of

    EVAPORATOR COIL That part of an evaporator constructed of pipe or tubing not enclosed in a pressure vessel. EVAPORATIVE CONDENSER A condenser that obtains cooling effect by the evaporation of water in an air stream on the external surface of the tubes for the heat removal necessary to liquefy refrigerant vapor on the inside of the tubes.

    Get Price
  • Product Catalogue - Henry Group

    connecting pipe work. • Allows for quick and easy installation. • At a glance the valves position can be determined when cap is removed. • Quick simple operation gives the operator full control. • Flow indicator arrow ensures the valve is in the position it is meant to be in – open or closed.

    Get Price
  • THE GOLD STANDARD: Project Design Document for Gold Standard

    • The gas extracting pipe consists of pipes that connect groups of gas wells to the manifolds, and each pipe was drilled with loophole to maximize gas collection. The manifolds are primary connected into a main pipe and then into the main header pipe;

    Get Price
  • Ammonia in Drinking-water - WHO

    Cement mortar used for coating the insides of water pipes may release considerable amounts of ammonia into drinking-water and compromise disinfection with chlorine (10). The presence of elevated ammonia levels in raw water may interfere with the operation of manganese-removal filters because too much oxygen is consumed by nitrification

    Get Price
  • Advanced Disinfection Study Guide

    3NaHSO3 + 3H2O + NH3 + 3Cl2 -- 3NaHSO4 + 5HCl + NH4Cl The theoretical dosage for dechlorination requires 1.78 parts of pure sodium sulfite per part chlorine or chloramines. In practice, the feed rate should be 10% in excess to ensure total chlorine removal. The reaction is almost instantaneous as with sulfur dioxide. C. Sodium Metabisulfite

    Get Price
  • Guide to Good Leak Testing - US EPA

    - ¼” pipe, tighten to 14 to 18 Nm - 3/8” pipe, tighten to 34 to 43 Nm - ½” pipe, tighten to 49 to 61 Nm - 5/8” pipe, tighten to 68 to 82 Nm. • When replacing flared components, used flare solder adaptors rather than manually made flares. The photos show a standard

    Get Price
  • Piping Evaporative Condensers

    2. STEEL PIPE 1-1/2 INCH (38mm) AND SMALLER SCH. 80, 2 INCH (50mm) AND LARGER SCH. 40. Condenser Liquid Drain Line for Steel Pipe Copper Tubing Two Phase Sewer Flow There are a lot of condensers operating with the drain lines reduced in the horizontal portion by concentric reducers and with horizontal valves as well. (See Figure 8)

    Get Price
  • Urea Mixing Design - Energy

    spray(injector), exhaust pipe/cone and mixer, but not just mixer itself. – Impact factors for SCR efficiency •SCR catalyst (formulation, deactivation …) •Temperature (exhaust temperature, heat loss) •Space velocity •NH3 storage level (urea dosing control algorithm) •Local NH3/NOx ratio (urea mixing) – Impact factors for urea mixing

    Get Price
  • Nitrate and nitrite in drinking-water - World Health Organization

    formed chemically in distribution pipes by Nitrosomonas bacteria during stagnation of nitrate-containing and oxygen-poor drinking-water in galvanized steel pipes or if chloramination is used to provide a residual disinfectant and the process is not sufficiently well controlled. 1.4 Environmental fate

    Get Price
  • Launch Vehicle Avionics for Passive Thermal Management

    3 . ADVANCED COOLING TECHNOLOGIES, INC. ISO9001-2008 AS9100-C Certified . Pre-Launch Heat Sink Heat Sink – Purge duct nitrogen sink: 67° F (~19.4°C)

    Get Price
  • Piping Evaporative Condensers

    2. STEEL PIPE 1-1/2 INCH (38mm) AND SMALLER SCH. 80, 2 INCH (50mm) AND LARGER SCH. 40. Condenser Liquid Drain Line for Steel Pipe Copper Tubing Two Phase Sewer Flow There are a lot of condensers operating with the drain lines reduced in the horizontal portion by concentric reducers and with horizontal valves as well. (See Figure 8)

    Get Price
  • IIAR Bulletin #114 - Pipe Markers

    Abbreviating the names given to pipes in the ammonia refrigeration system will assist the operator in identifying and tracing the system. To further assist the operator make sure the physical state (LIQUID or VAPOR) as well as the pressure level (HIGH or LOW) are also identified in the marker. i.e., Adding -10° to a particular recirculated suction line and 0° to another one, would serve to

    Get Price
  • Pipe Sizing Steam Supply andCondensateReturn Lines

    Table 46-1. Steam Pipe Capacity at 180 psig—Schedule 40 Pipe Pipe Size Pressure drop per 100 ft of pipe length (in) 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 88 202 407 895 1,394 2,820 4,650 8,550 12,740 18,000 33,300 54,600 113,900 207,000 5 56 128 258 566 882 1,785 2,940 5,390 8,050 11,400 21,080 34,600 72,000 131,300 2 39 90 182 400 624 1,260

    Get Price
  • THE GOOD, THE BAD, AND THE UGLY OF USING ANHYDROUS AMMONIA

    3. In a 1992 incident at a meat packing plant, a forklift struck and ruptured a pipe carrying ammonia for refrigeration. Workers were evacuated when the leak was detected. A short time later, an explosion occurred that caused extensive damage, including large holes in two sides of the building. The forklift was believed to be the source of

    Get Price